Wood fiber FiberTherm Install
Wood fiber panels with density of 140 Kg/m³.
Fibertherm Install is a wood fiber panel for internal thermal insulation of walls and roofs. Available with either a smooth surface or a milled surface.
Related articles
The FiberTherm Install wood fiber panel is a thermo-acoustic insulation for the internal lining of roofs and walls. FiberTherm Install panels are available with either smooth or milled surfaces.
The material is also recyclable, with relative NaturePlus certification and made exclusively with wood from controlled forests in compliance with the FSC directives.
• ideal for preparing wooden assembly levels (eg solid wood walls);
• can be fixed as an internal lining;
• no independent frame is required;
• quick, cheap;
• ideal for prefabricating assembly structures;
• the ducts can be easily milled;
• individual millings on request;
• recyclable, ecological, respects the environment;
• tested and authorized building material based on current European standards.
insulating panels with smooth surface
Thickness (mm) | Dimension (mm) | Weight/m²(kg) | Panels/Pallet | m²/Pallet | Weight/Pallet(kg) |
---|---|---|---|---|---|
50 | 2600x600 | 7,00 | 44 | 68,6 | approx.490 |
insulating panels with milled surface
Thickness (mm) | Dimension (mm) | Weight/m²(kg) | Panels/Pallet | m²/Pallet | Weight/Pallet(kg) |
---|---|---|---|---|---|
50 | 1250x2595 | 5,60 | 22 | 71,3 | approx.410 |
General indications:
• stack horizontally and dry;
• pay particular attention to the edges of the panels;
• remove the pallet packaging only when it is on a flat, stable and dry surface.
Density (kg/m³) | approx. 140 |
Reaction to fire according to the EN standard 13501-1 | E |
Coefficient of thermal conductivity λD W/(m∗K) | 0,040 |
Specific heat c [J/(kg∗K)] | 2.100 |
Resistance to vapor diffusion μ | 3 |
sd value (m) | 0,15 |
Thermal resistance RD [(m² · K)/W] | 1,25 |
Compression strenght (kPa) | ≥100 |
Traction resistance perpendicular to the faces (kPa) | 10 |
Length correlated with flow resistance [(kPa · s)/m²] | ≥100 |
Short-term water absorption (kg/m²) | ≤2,0 |
Manufacturing controlled according to the legislation | EN 13171 |
Panels identification | WF-EN13171-T5-CS(10/Y)100-TR10-MU3 |
Waste code (EAK) | 030105 /170201 |